The Effect Of Distributed Generation (DG) Placement On Electricity Reliability

Authors

  • Agung Nugroho Diponegoro University
  • Ajub Ajulian ZM Diponegoro University
  • Bambang Winardi Diponegoro University

DOI:

https://doi.org/10.55642/eatij.v5i01.288

Keywords:

Distributed Generation (DG), reliability index, ETAP 12.6.0

Abstract

The continuity of the supply of electric power is becoming a greater demand from consumers. Feeder MRA05 GI Mrica Banjarnegara supplies electrical energy for parts of Banjarnegara Regency until 2020 has 4 distributed generations, namely PLTMH Sigebang 500 KW, PLTMH Kincang 320 KW, PLTMH Adipasir 320 KW, PLTMH Rakit 500 KW. Based on recorded data in 2020, the MRA05 feeder experienced 15 blackouts/year, with a total outage duration of 38.68 hours/year, of course it was enough to disrupt the continuity of the distribution of electrical energy to consumers. This research discusses the magnitude of the reliability index (SAIFI, SAIDI, CAIDI) when the DG is not installed and installed. The calculation of the magnitude of the reliability index was carried out using the Reliability Index Assessment (RIA) method, the calculation results were compared with the results of the ETAP 12.6.0 software simulation. The reliability index is based on the RIA method when DG is not installed, the SAIFI value is 2.96228 interruptions/year, the SAIDI value is 9.1185 hours/year, the CAIDI value is 3.078 hours/interruption, When DG is installed, the SAIFI value is 2.96228 disturbances/ year, the SAIDI value is 7.567 hours/year, the CAIDI value is 2.5546 hours/interruption.

Downloads

Download data is not yet available.

References

Ifanda, dkk. “Kajian Outage management Sistem Kelistrikan”.Serpong: Badan Pengkajian dan Penerapan teknologi (BPPT).2014.

Praditama, Fery. “Analisis Keandalan dan Nilai Ekonomis di Penyulang Pujon PT. PLN (Persero) Area Malang”. Universitas Brawijaya, 2012

Aziz, Thariq Fathony, Penentuan Target Indeks keandalan, Drop Tegangan, dan Rugi Daya pada feeder SRL07 GI srondol menggunakan ETAP 7.5.0, Tugas Akhir, Universitas Diponegoro, Semarang, 2015.

Putro, A. P., Analisis Tegangan Jatuh Sistem Distribusi Listrik Kabupaten Pelalawan dengan Menggunakan ETAP 7.5.0., Skripsi, Universitas Diponegoro, Semarang, 2015.

Tim Penyusun,Diklat Profesi Pengoperasian Jaringan dan Sambungan Tegangan Rendah, PT. PLN (Persero) Pusat Pendidikan dan Pelatihan, 2012.

Chowdury, Ali A. dan Koval, Don O., Power Distribution System Reliability, John Wiley & Sons Inc. Publication, New Jersey, 2009.SPLN 68-2:1986. Tingkat jaminan sistem tenaga listrik.

Short, Thomas A., Electric Power Distribution Handbook Second Edition, CRC Press Taylor & Francis Group, USA, 2014.

Afriana, Elza, “Perbandingan Indeks Keandalan Sistem Distribusi pada Penyulang SEL03 dalam Keadaan Perfect switching dan Imperfect switching”, Tugas Akhir, Universitas Diponegoro, Semarang, 2017.

SPLN 59 : 1985. Keandalan pada Sistem Distrbusi 20 kV dan 6 kV

Downloads

Published

2023-03-16